SolarEx logo

 

Spa Tanning Mist Overspray Filtration Booth

Overspray shield which vastly reduces overspray and particle deposits in the salon or spa.
Essential to keep the busy salon environment clean and mist free.

Unit S2000

Air Filtration Booth

Download Printable PDF Specs of SolarEx Model S2000

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

                  SolarEx Spa Spray Tan Overspray Booth

SolarEx Spa Spray Tan Overspray Booth

Model No S2000

NOTE: This unit is recirculatory; i.e. filtered air is exhausted back into the workplace.

Description

Steel construction of the central filtration tower, finished in black with “sparkling” silver front baffle plates – particulate and moisture filters – 2 x high efficiency backward curved fans, UL, VDE and CSA approved – sealed electric wiring and external foot operated switch – lightweight, aluminium composite side panels – aluminium composite floor panel & ribbed rubber mat.

Operation

All WS filtration and extraction systems carry a lifetime warranty, are quiet in operation and can be assembled in seconds.
Space saving, free standing booth can be sited in a corner in the Beauty Salon or Spa. Once power cables are connected the booth is simply switched on and off via a latching footswitch.

S2000 Weight = 100 kgs

Solarex S2000 Spray Tan Overspray Booth schematic drawing
Filtration

The particulate (intake) filter is a three stage graduated fibre filter with a high 'dust' holding capacity for long life. Filtration to 5 micron particles. NB: Spray particulate sizes vary from 10 to 20 microns. The final filtration stage absorbs any residual moisture.
Through the process of filtration, absorption and dilution, technician / therapist and client exposure to airborne tanning overspray is vastly reduced and general salon cleanliness hugely enhanced.

Specification

Model
No.
Fan Motor  *
Spec.
Air Volume
at Free Air
Ave. Air Velocity
at Filter Face
Noise Level
LA eq dB(A)
S2000 230V 50Hz 150W 1100 m3/hr 0.6 m/sec 65

* 110V 60Hz available if required.

CoSHH requirementsDemonstrating adequate control of the risks to the health of employees students and the general public, from dusts, powders, mists, fumes and vapours is the fundemental requirement of the Control of Substances Hazardous to Health (CoSHH).

Download Printable PDF Specs of SolarEx Model S2000

 
Please contact WS for advice on the choice of machine for any given situation.
We go to great lengths to ensure accuracy in our literature, however we cannot be held responsible for errors or omissions. Information is given for guidance only and we reserve the right to alter specification.