SolarEx logo

 

Salon Tanning Mist Filtration Booth

The spray shield that vastly reduces overspray and particle deposits.
Essential for a clean, healthy salon environment.

Unit S1000

Air Filtration Booth

Download Printable PDF Specs of SolarEx Model S1000

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SolarEx S1000 Spray Tan Filtration Booth

SolarEx Spray Tan Filtration Booth

Model No S1000

NOTE: This unit is recirculatory; i.e. filtered air is exhausted back into the workplace.

Description

Steel construction of central filtration tower, finished in black powder coating and complete with materials storage cabinet -- particulate and moisture filters - incorporating 3 x external rotor motor axial fans, brushless, UL, VDE and CSA approved - sealed electrical wiring and external foot operated switch – frosted translucent side panels - ribbed rubber mat.

Operation

All WS filtration and extraction systems carry a lifetime warranty, are quiet in operation and can be assembled in seconds.
Space saving, free standing booth can be sited in beauty room corner. Once power cables are connected the booth is simply switched on and off via a latching footswitch.

S1000 Weight = 125kgs

Solarex1000 Dimensions
Filtration

The particulate (intake) filter is a three stage graduated fibre filter with a high 'dust' holding capacity for long life. Filtration to 5 micron particles. NB: Spray particulate sizes vary from 10 to 20 microns. The final filtration stage absorbs any residual moisture.
Through the process of filtration, absorption and dilution, technician / therapist and client exposure to airborne tanning overspray is vastly reduced and general salon cleanliness hugely enhanced.

Specification

Model
No.
Fan Motor  *
Spec.
Air Volume
at Free Air
Ave. Air Velocity
at Filter Face
Noise Level
LA eq dB(A)
S1000 230V 50Hz 120W 975 m3/hr 0.65 m/sec 63

* 110V 60Hz available if required.

CoSHH requirementsDemonstrating adequate control of the risks to the health of employees students and the general public, from dusts, powders, mists, fumes and vapours is the fundemental requirement of the Control of Substances Hazardous to Health (CoSHH).

Download Printable PDF Specs of SolarEx Model S1000

 
Please contact WS for advice on the choice of machine for any given situation.
We go to great lengths to ensure accuracy in our literature, however we cannot be held responsible for errors or omissions. Information is given for guidance only and we reserve the right to alter specification.