Advantage ORACLE
laser fume extraction systems
The complete, global solution for high performance laser fume extraction.
Introducing our most technically
advanced Laser Fume Extractor.
The AD Oracle packs a powerful
range of unique features into one
compact unit.
The revolutionary Auto-Voltage Sensing Pump automatically self adjusts to run on any voltage worldwide, whilst the Reverse Flow filter technology enhances filter performance and ensures longer filter life.
Closed Loop, Automatic Flow Control allows the user to pre-set correct flow rates, for lower noise levels and further protection of both the combined filter and the 2 stage F8 pre filter, which has a massive 12m² of surface area..
The following features all come as standard:
• Auto sensing voltage (90-257v) for global use
• Closed Loop Automatic Flow Control
• 2 Stage F8 Pre Filter with 12m² of surface area
• Reverse Flow
• ‘Easi-Seal’ Filter Location
• Small Footprint and Low Noise levels
Download Printable PDF Specs for TechFlo Model T1954-A
Model No: T1954-A
TechFlo Air Filtration UnitsModel No: T1954-A |
|---|
| NOTE: These units are recirculatory; i.e. filtered air is exhausted back into the workplace. |
Part Numbers
Model – Stainless Steel (SS) or
Powder Coated (PC) Options |
24V Start/Stop |
Filter Change/System Failure Signal |
VOC Monitoring |
Hose Kit* |
Pre Filter |
Combined Filter |
|---|---|---|---|---|---|---|
T1954A-SS |
A2001 |
A2002 |
A2003 |
A1020008 75-50mm |
A1030 156 |
A1030155 |
T1954A-PC |
A2001 |
A2002 |
A2003 |
A1020008 75-50mm |
A1030 156 |
A1030155 |
Technical Data
| EC | US | |
|---|---|---|
| Dimensions (hxwxd) | 980x430x430mm | 38.5”x17”x17” |
| Cabinet Construction | Brushed Stainless Steel/Powder Coated Mild Steel | Brushed Stainless Steel/Powder Coated Mild Steel |
| Blower | 1.1kw 380m³/hr | 1.1kw/223cfm |
| Electronics | 100-240 1ph 50/60Hz Full Load current: 12.5amps |
100-240 1ph 50/60Hz Full Load current: 12.5amps |
Filtration

Through the process of filtration, adsorption and dilution, operator exposure to potentially hazardous substances is vastly reduced or eliminated.
Filter Specifications*
Pre Filter |
Combined Filter |
|||
|---|---|---|---|---|
Surface Media Area |
12m2 approx |
HEPA Filter Media |
Glass Fibre |
|
Filter Media |
Glass Fibre |
HEPA Media Construction |
Maxi Pleat Construction with Webbing
Spacers |
|
Filter Media Construction |
Maxi Pleat |
Filter Efficiency |
H13 (99.997% @ 0.3 microns) |
|
Housing |
Zintec mild steel |
Treated Activated Carbon |
15kgs |
|
Filter Efficiency |
F8 (95% @ 0.8 microns) |
Filter Housing |
Zintec Mild Steel |
|
*All units fitted with standard filter combinations
Air Flow through Filters Technical Specification

Other filters are available. Please call us for details
These units are designed for immediate operator protection from concentrations of airborne contaminants whereby all gases, fumes, vapours and particulates on top of the unit are drawn into the intake filter. Cleaned air is exhausted to the base of the bench. Higher grade filters are available on request.
Demonstrating adequate control of the risks to the health of employees students and the general public, from dusts, powders, mists, fumes and vapours is the fundemental requirement of the Control of Substances Hazardous to Health (CoSHH).
Download Printable PDF Specs for TechFlo Model T1954-A
| Please contact WS for advice on the choice of machine for any given situation. |