TechFlo Product Logo

Advantage ORACLE
laser fume extraction systems

The complete, global solution for high performance laser fume extraction.

Advantage ORACLE laser fume extraction systemsIntroducing our most technically advanced Laser Fume Extractor. The AD Oracle packs a powerful range of unique features into one compact unit.

The revolutionary Auto-Voltage Sensing Pump automatically self adjusts to run on any voltage worldwide, whilst the Reverse Flow filter technology enhances filter performance and ensures longer filter life.

Closed Loop, Automatic Flow Control allows the user to pre-set correct flow rates, for lower noise levels and further protection of both the combined filter and the 2 stage F8 pre filter, which has a massive 12m² of surface area..

The following features all come as standard:
• Auto sensing voltage (90-257v) for global use
• Closed Loop Automatic Flow Control
• 2 Stage F8 Pre Filter with 12m² of surface area
• Reverse Flow
• ‘Easi-Seal’ Filter Location
• Small Footprint and Low Noise levels

Download Printable PDF Specs for TechFlo Model T1954-A

Model No: T1954-A

 

TechFlo Air Filtration Units

Model No: T1954-A

NOTE: These units are recirculatory; i.e. filtered air is exhausted back into the workplace.

Part Numbers

Model – Stainless Steel (SS) or Powder Coated (PC) Options
24V Start/Stop
Filter Change/System
Failure Signal
VOC Monitoring
Hose Kit*
Pre Filter
Combined Filter
T1954A-SS
A2001
A2002
A2003
A1020008
75-50mm
A1030
156
A1030155
T1954A-PC
A2001
A2002
A2003
A1020008
75-50mm
A1030
156
A1030155

Technical Data

  EC US
Dimensions (hxwxd) 980x430x430mm 38.5”x17”x17”
Cabinet Construction Brushed Stainless Steel/Powder Coated Mild Steel Brushed Stainless Steel/Powder Coated Mild Steel
Blower 1.1kw 380m³/hr 1.1kw/223cfm
Electronics 100-240 1ph 50/60Hz
Full Load current: 12.5amps
100-240 1ph 50/60Hz
Full Load current: 12.5amps

Filtration

Ad Oracle Filtration system

Through the process of filtration, adsorption and dilution, operator exposure to potentially hazardous substances is vastly reduced or eliminated.

Filter Specifications*

Pre Filter
Combined Filter
Surface Media Area
12m2 approx
 
HEPA Filter Media
Glass Fibre
Filter Media
Glass Fibre
HEPA Media Construction
Maxi Pleat Construction with Webbing Spacers
Filter Media Construction
Maxi Pleat
Filter Efficiency
H13 (99.997% @ 0.3 microns)
Housing
Zintec mild steel
Treated Activated Carbon
15kgs
Filter Efficiency
F8 (95% @ 0.8 microns)
Filter Housing
Zintec Mild Steel

*All units fitted with standard filter combinations

Air Flow through Filters                              Technical Specification

air Flow through Filters
Other filters are available. Please call us for details

These units are designed for immediate operator protection from concentrations of airborne contaminants whereby all gases, fumes, vapours and particulates on top of the unit are drawn into the intake filter. Cleaned air is exhausted to the base of the bench. Higher grade filters are available on request.

CoSHH requirementsDemonstrating adequate control of the risks to the health of employees students and the general public, from dusts, powders, mists, fumes and vapours is the fundemental requirement of the Control of Substances Hazardous to Health (CoSHH).

Download Printable PDF Specs for TechFlo Model T1954-A

 

Please contact WS for advice on the choice of machine for any given situation.
We go to great lengths to ensure accuracy in our literature, however we cannot be held responsible for errors or omissions. Information is given for guidance only and we reserve the right to alter specification.